(2015) Monte Carlo and experimental internal radionuclide dosimetry in RANDO head phantom. Australasian Physical and Engineering Sciences in Medicine. pp. 465-472.
![]() |
Text
321.pdf Download (2MB) |
Abstract
Monte Carlo techniques are widely employed in internal dosimetry to obtain better estimates of absorbed dose distributions from irradiation sources in medicine. Accurate 3D absorbed dosimetry would be useful for risk assessment of inducing deterministic and stochastic biological effects for both therapeutic and diagnostic radiopharmaceuticals in nuclear medicine. The goal of this study was to experimentally evaluate the use of Geant4 application for tomographic emission (GATE) Monte Carlo package for 3D internal dosimetry using the head portion of the RANDO phantom. GATE package (version 6.1) was used to create a voxel model of a human head phantom from computed tomography (CT) images. Matrix dimensions consisted of 319 � 216 � 30 voxels (0.7871 � 0.7871 � 5 mm3). Measurements were made using thermoluminescent dosimeters (TLD-100). One rod-shaped source with 94 MBq activity of 99mTc was positioned in the brain tissue of the posterior part of the human head phantom in slice number 2. The results of the simulation were compared with measured mean absorbed dose per cumulative activity (S value). Absorbed dose was also calculated for each slice of the digital model of the head phantom and dose volume histograms (DVHs) were computed to analyze the absolute and relative doses in each slice from the simulation data. The S-values calculated by GATE and TLD methods showed a significant correlation (correlation coefficient, r2 � 0.99, p < 0.05) with each other. The maximum relative percentage differences were �14 for most cases. DVHs demonstrated dose decrease along the direction of movement toward the lower slices of the head phantom. Based on the results obtained from GATE Monte Carlopackage it can be deduced that a complete dosimetry simulation study, from imaging to absorbed dose map calculation, is possible to execute in a single framework. © 2015, Australasian College of Physical Scientists and Engineers in Medicine.
Item Type: | Article |
---|---|
Keywords: | Brain; Computerized tomography; Diagnosis; Dosimetry; Nuclear medicine; Risk assessment; Stochastic systems; Tomography, Absorbed dose; Absorbed dose distribution; Correlation coefficient; Dose-volume histograms; GATE; Geant4 application for tomographic emissions; Rando phantom; Thermoluminescent dosimeters, Monte Carlo methods, technetium 99m; radioisotope, Article; comparative study; computed tomography scanner; computer simulation; controlled study; dose volume histogram; dosimetry; experimental design; Geant4 application for tomographic emission Monte Carlo; histogram; image analysis; imaging phantom; measurement accuracy; Monte Carlo method; priority journal; quantitative analysis; radiation absorption; radiation dose distribution; thermoluminescence dosimeter; three dimensional internal radionuclide dosimetry; uncertainty; voxel based morphometry; biological model; chemistry; devices; head; human; Monte Carlo method; physiology; radiometry; radiotherapy dosage, Head; Humans; Models, Biological; Monte Carlo Method; Phantoms, Imaging; Radioisotopes; Radiometry; Radiotherapy Dosage |
Page Range: | pp. 465-472 |
Journal or Publication Title: | Australasian Physical and Engineering Sciences in Medicine |
Volume: | 38 |
Number: | 3 |
Publisher: | Kluwer Academic Publishers |
Depositing User: | ms soheila Bazm |
URI: | http://eprints.ssu.ac.ir/id/eprint/9338 |
Actions (login required)
![]() |
View Item |