(2015) The comparison of standard lead with individual mold shielding on patient dose. Iranian Journal of Radiation Research. pp. 197-200.
![]() |
Text
309.pdf Download (577kB) |
Abstract
Background: The Shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. These methods include Lead standard blocks, individual molding and multi leaf collimator (MLC). The MLC method is not still common in Iran radiotherapy centers. Individual molding is be"er than the lead block shielding because of lower operator error and time consuming. Materials and Methods: This study was performed in Shahid Ramazanzade radiotherapy center of Yazd and intended to compare radiation dose due to the two shielding methods of lead and Cerrobend. The radiation field sizes of head and neck, pelvis, and breast cancer treated by Cobalt unit, 9MV, and 6MV photon beams of Neptun and Compact linear accelerators were studied, respectively. The Absolute and Relative dosimetry were achieved by Farmer ionic chamber and diod detector. Results: The Absolute and Relative dose values which were measured at the two shielding methods of lead standard and Cerrobend individual molding were similar without significantly difference. Conclusion: The miss difference dose between these two methods shielding and the advantages such as saving time, precision, and accuracy lead to preference of individual molding method rather than the lead block shielding. © 2015, Novim Medical Radiation Institute. All rights reserved.
Item Type: | Article |
---|---|
Keywords: | analysis of variance; Article; breast cancer; Cerrobend molding block; clinical article; controlled study; dosimetry; head and neck cancer; health care facility; human; Iran; lead standard block; linear accelerator; multileaf collimator; pelvis cancer; radiation absorption; radiation detector; radiation dose; radiation exposure; radiation field; radiation shield; X ray beam limiting device; breast cancer; cancer patient; cobalt therapy; cobalt-60 unit; head and neck cancer; ionization chamber; pelvis cancer; photon therapy; radiation dose, lead; water |
Page Range: | pp. 197-200 |
Journal or Publication Title: | Iranian Journal of Radiation Research |
Volume: | 13 |
Number: | 2 |
Publisher: | Novim Medical Radiation Institute |
Depositing User: | ms soheila Bazm |
URI: | http://eprints.ssu.ac.ir/id/eprint/9289 |
Actions (login required)
![]() |
View Item |