Repository of Research and Investigative Information

Repository of Research and Investigative Information

Shahid Sadoughi University of Medical Sciences

Mechanical vibration as an adjunct to clear aligner treatment for accelerating tooth movement: A review

(2022) Mechanical vibration as an adjunct to clear aligner treatment for accelerating tooth movement: A review. Dental Research Journal. p. 75. ISSN 1735-3327 (Print) 2008-0255 (Electronic) 1735-3327 (Linking)

Full text not available from this repository.

Official URL: https://www.ncbi.nlm.nih.gov/pubmed/36407773

Abstract

Many patients, particularly adults, may prefer clear aligner treatment due to its esthetics and ease of use. Some studies have shown that mechanical vibration can affect the rate of tooth movement and other aspects of orthodontic treatment. The purpose of this systematic review was to substantiate the effects of vibration as an adjunct to clear aligner treatment. A comprehensive search of the PubMed, Embase, Cochrane library, and Scopus and also hand searching of reference lists was conducted for finding published studies up to March 2021. Two authors reviewed the titles and abstracts independently to select relevant studies and the full texts where there was some skepticism. Seven papers were included in this study following removing duplicates and irrelevant studies, four of which were randomized controlled trial and three were retrospective studies. In the majority of studies, High-Frequency Vibration (HFV) has shown to be effective in accelerating tooth movement and reducing the exchange interval of aligners. Little data have advocated that HFV can increase bone density, reduce pain or root resorption. It seems that HFV is more effective than low frequency vibration in patients treated with clear aligners. Based on a low level of certainty, HFV can increase the rate of tooth movement and decrease the exchange interval of clear aligners. Further investigation is necessary to clarify the effects of vibration on pain and discomfort, bone density, and root resorption.

Item Type: Article
Keywords: Clear aligner appliances orthodontic tooth movement vibration real or perceived, financial or nonfinancial in this article.
Page Range: p. 75
Journal or Publication Title: Dental Research Journal
Volume: 19
ISSN: 1735-3327 (Print) 2008-0255 (Electronic) 1735-3327 (Linking)
Depositing User: Mr mahdi sharifi
URI: http://eprints.ssu.ac.ir/id/eprint/30866

Actions (login required)

View Item View Item