AIM: To evaluate Orbscan II corneal topography in hyperopic cases. METHODS: A retrospective, observational, consecutive, clinical case series in 295 eyes of hyperopic patients who undergo a LASIK evaluation. The information that was reviewed included age, sex of the patients and the Orbscan II corneal topographic maps. Refractive powers and the following test indices produced by Orbscan II were analyzed: keratometry, corneal diameter, pupil diameter and anterior chamber depth. RESULTS: The total mean corneal thickness was 546.3 +/- 35.5 mu m. It was found; 547.3 +/- 38.41 mu m in 17-29 years old, 553.4 +/- 38.3 mu m in 30-44 years old and 546.2 +/- 29.3 mu m in older than 45 years old. The mean corneal thickness was found 551.5 +/- 35.9 mu m in female, and 542.6 +/- 34.7 mu m in male. The total mean depth of anterior chamber was 2.57 +/- 0.40mm and in 17-29 years old patients was 2.82 +/- 0.39mm. In 30- 44 years old patients was 2.49 +/- 0.39mm and in patients older than 45 years old was 2.37 +/- 0.40mm. The mean depth of anterior chamber was 2.53 +/- 0.40mm in female and 2.60 +/- 0.40mm in male. A reverse significant relation between corneal thickness and keratometry were found. Refractive error severity had a reverse correlation with depth of anterior chamber and a correlation with keratometry (P=0.061, r=0.108).Corneal thickness had a reverse correlation with keratometry (P=0.005, r=0.160), and correlation with pupil diameter (P=0.013, r=0.144). CONCLUSION: We provides a description and analysis of Orbscan II findings in hyperopic patients. These show mean corneal thickness 546.3 +/- 35.5 mu m and anterior chamber depth 2.57 +/- 0.40mm in hyperopic patients.

Item Type: Article
Keywords: Orbscan II corneal topography hyperopia anterior-chamber depth orbscan-ii human eye refractive status axial length aberrations system parameters thickness lens Ophthalmology
Page Range: pp. 359-361
Journal or Publication Title: International Journal of Ophthalmology
Journal Index: WoS
Volume: 2
Number: 4
ISSN: 2222-3959
Depositing User: Mr mahdi sharifi
URI: http://eprints.ssu.ac.ir/id/eprint/28621

Actions (login required)

View Item View Item