An unusual urethral foreign body �AA battery� associated with urethral stenosis: A case report

(2022) An unusual urethral foreign body �AA battery� associated with urethral stenosis: A case report. Urology Case Reports.

[img] Text
An unusual urethral foreign body.pdf

Download (975kB)

Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Urethral foreign bodies are rare with a variety of causes, including psychiatric illness, autoeroticism, intoxication, and perceived contraception, we present a 49-yr-old man who went to the emergency ward 9-month ago inserting an AA battery in his urethra. The battery was removed without surgery after 24 hours. The patient was then referred to the hospital after 5 months with complaints of obstructive urinary symptoms such as decreased urinary caliber, diagnosed with penile urethral stricture, and undergoes dilatation of the urethra. Usually, in the case of urethral stricture, the initial steps including urethral dilation and internal urethrotomy can be used. © 2021 The Authors

Item Type: Article
Keywords: adult; Article; case report; clinical article; cystostomy; dilatation; dysuria; follow up; foreign body; hematuria; human; intermittent catheterization; male; middle aged; urethra; urethra stenosis; urethrotomy; urinalysis; urinary tract infection; X ray